Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Ray-Ran (Industrial Physics) - Anh Quốc

Với máy ép mẫu thử Ray-Ran, bạn có thể sản xuất các mẫu thử nghiệm phòng thí nghiệm hoàn hảo, bao gồm các tấm màu, mẫu thử kéo và va đập, cũng như các linh kiện nhỏ cho các quy trình thử nghiệm cơ học.
Liên hệ

Hãng sx: Ray-Ran (Industrial Physics) - Anh Quốc

Khi bạn cần tạo các rãnh tập trung ứng suất trong các mẫu thử va đập Charpy và Izod, hãy tìm đến Máy cắt rãnh tự động hàng đầu trong ngành của chúng tôi.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

PN-HT300AF Máy đo độ bền kéo ngang tự động được thiết kế và phát triển dựa trên các tiêu chuẩn quốc gia mới nhất như GB/T 12914, GB/T 2792 và ISO 1924-2.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy đo độ bền nén ống giấy PN-CT500F là một thiết bị kiểm tra độ bền nén của ống giấy, được thiết kế và phát triển theo các tiêu chuẩn GB/T 22906.9, BB/T0032 và ISO 11093.9. Máy này dùng để xác định khả năng chịu nén của các ống giấy, đặc biệt trong các ứng dụng như bao bì, đóng gói và kiểm soát chất lượng. Nó là công cụ quan trọng trong ngành công nghiệp sản xuất giấy và bao bì để đảm bảo rằng các sản phẩm ống giấy đáp ứng được các yêu cầu về độ bền và tính ổn định trong điều kiện sử dụng.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy đo độ bền kéo ngang PN-HT300F được thiết kế và phát triển theo các tiêu chuẩn quốc gia GB/T12914, GB/T2792 và ISO1924-2 để đo lực kháng kéo, độ bền kéo, độ giãn dài, chiều dài nứt, năng lượng hấp thụ kéo, chỉ số độ bền kéo, chỉ số năng lượng hấp thụ kéo, độ bền bong tróc 180°, độ bền niêm phong nhiệt, và các đặc tính khác của giấy. Máy này được sử dụng rộng rãi trong các ngành công nghiệp giấy, bìa carton, phim nhựa và các vật liệu phi kim loại khác để đo độ bền kéo, độ giãn dài và năng lượng hấp thụ kéo. Thiết bị sử dụng sản phẩm cơ điện tử, áp dụng các khái niệm thiết kế cơ học hiện đại và nguyên lý thiết kế công thái học, đồng thời sử dụng bộ xử lý ARM tốc độ cao tiên tiến, giúp thiết kế máy thử kéo này hợp lý và tỉ mỉ. Đây là thế hệ máy thử kéo mới với thiết kế sáng tạo, dễ sử dụng, hiệu suất xuất sắc và hình thức đẹp mắt. Các chế độ làm việc của thiết bị bao gồm: chế độ kéo, chế độ bong tróc, và chế độ kéo ướt.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

PN-ST500F là một thiết bị kiểm tra độ cứng đa chức năng, thích hợp để đo độ cứng uốn của giấy, bìa cứng và các vật liệu phi kim loại khác có độ dày dưới 2mm. Độ cứng là lực hoặc mô-men cần thiết để uốn một mẫu có kích thước xác định đến một góc nhất định, và nó là chỉ số về hiệu suất chịu lực khi uốn của giấy và bìa cứng.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

PN-BBTF Ball Burst Tester là một loại máy kiểm tra độ bể vỡ của giấy tissue mới được phát triển dựa trên tiêu chuẩn quốc gia GB/T 24328.7 và ISO 126259. Máy này được thiết kế đặc biệt để kiểm tra độ bể vỡ của các sản phẩm giấy tissue, bao gồm giấy vệ sinh, khăn giấy nhà bếp, khăn tay giấy, giấy ăn, khăn lau và các sản phẩm giấy tissue khác. Những sản phẩm này có thể là giấy một lớp hoặc nhiều lớp, với các dạng giấy có thể là cuộn hoặc tờ, gấp hoặc không gấp, có dập nổi hoặc không, in ấn hoặc không in.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

Máy kiểm tra độ nghiền bột PN-SDJ100 được thiết kế để xác định tốc độ thoát nước của một dung dịch pha loãng bột giấy và biểu thị tốc độ này bằng giá trị Schopper-Riegler (SR). Máy kiểm tra này tuân thủ các quy định trong ISO 5267/1 và GB3332, các tiêu chuẩn liên quan đến việc đo độ thấm nước của bột giấy.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

PN-DPT Toilet Paper Dispersity Tester được phát triển theo tiêu chuẩn quốc gia mới nhất GB / T 20810 cho giấy vệ sinh. Thiết bị này chủ yếu được sử dụng để kiểm tra khả năng phân tán của giấy vệ sinh cuộn, giấy vệ sinh phẳng, giấy vệ sinh dạng đĩa và các sản phẩm khác. Khả năng phân tán của giấy vệ sinh là khả năng của nó chuyển thành dạng mảnh trong nước. Nếu khả năng phân tán của giấy vệ sinh kém, điều này có thể gây tắc nghẽn trong toilet. Máy kiểm tra khả năng phân tán giấy vệ sinh chủ yếu bao gồm ống quế, rôto, động cơ và đồng hồ đo lưu lượng khí.
Liên hệ

Hãng sx: Pnshar - Trung Quốc

-COBB là thiết bị để đo độ hấp thụ nước của giấy và bìa carton và bìa sóng, giấy rời, giấy thấm với khả năng hấp thụ nước cao nhưng không phù hợp với giấy có mật độ thấp hợp 50g/m2. Tiêu chuẩn : ISO535, GB/T1668, GB/T 1540, TAPPI 441
Liên hệ