STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

STADI P Máy nhiểu xạ X phân tích đặc tính chất xúc tác hiệu quả về chi phí

  • 295
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Nhiều loại đầu dò tia X đếm photon đơn.

● Bức xạ Kα1 tinh khiết sử dụng nguồn Co, Cu, Mo và Ag.

● Chế độ truyền/Debye-Scherrer hoặc Bragg-Brentano.

Introduction

The well-known, high-precision STOE STADI P two circle goniometer is the basis of STOE’s powder diffraction building block system (read more about it here). Vertically or horizontally mounted, the STADI P can be built in Transmission/Debye-Scherrer or Bragg-Brentano geometry. Moreover, two STADI P goniometers, either in the same or different configurations, can be mounted in the same cabinet resulting in two completely independent instruments. However, the two goniometers can also share one source.

  • Various single-photon-counting X-ray detectors
  • Pure Kα1 radiation using Co, Cu, Mo and Ag sources
  • The ultimate platform for laboratory PDF calculations using Ag Kα1 data
  • Transmission/Debye-Scherrer or Bragg-Brentano mode
  • Ideally suited for the analysis of air/moisture-sensitive and microsamples
  • A range of high- and low-temperature attachments available
  • ADVANTAGES OF TRANSMISSION-/ DEBYE-SCHERRER GEOMETRY

  • Same sample volume in the beam over the full 2θ scale
  • Reliable intensities with no necessity for further mathematical corrections
  • No line broadening for weak absorbers
  • No height displacement
  • Real micro-sampling possible
  • Lesser effects of preferred orientation

Specifications

stadip sandwich
 
2θ range 0° up to 140° 2θ
Goniometer 2 circles
Radius of measuring circle 260 mm
Radius of focusing circle 130 mm
X-ray sources Sealed Tubes: Co, Cu, Mo, Ag
Optics Primary monochromator
Software WinXPOW package
Dimensions (including system cabinet, max.) 1800 x 880 x 2050 mm
Weight (complete system) 780 – 940 kg
Detectors Silicon strip detector MYTHEN2 R 1K/2K/3K/4K
Accessories
  • High- and low-temperature attachments for reflection and capillary samples
  • Reaction chamber for capillary samples
  • Various sample stages
  • Various sample changers
Powder STADI P DSC 7323 RZ e1686834392423
The STADI P can be set up by itself or as a dual setup with two different geometries on the independent goniometers.
STADIP 1 e1681798921908
The horizontal STADI P set up with a capillary sample holder.
STADIP 2
The horizontal STADI P set up with STOE's transmission sample holder.
Mythen 3K e1686833321953
For ultra fast measurements of e.g. unstable samples STOE offers an installation with up to four MYTHEN detectors. With four MYTHEN detectors a single exposure will cover 0 - 73° in 2θ. (See the respective AppNote)

ADAMAnT

When an X-ray tube ages, it is possible that its take off angle changes, resulting in a 2 Theta shift of the reflex positions on the detector. To reverse the impact of this take off angle change, the monochromator and sample position have to be adapted through a Beam Optimization.
The STOE STADI P Beam Optimization has been a well-established tool of the WinXPOW software for a very long time. It automatically sets the Johann type monochromator to the maximum intensity of the Kα1-radiation of a sealed tube’s line focus by the help of a certified standard material – but the alignment of the goniometer axis into the beam path has – so far – still to be done manually with a luminance screen.
From now on, the unique ADAMAnT tool aligns monochromator and goniometer automated to the Kα1-radiation, making any contact with the open beam or its air scattered radiation no longer necessary, no matter whether it is only the exchange of a worn-out tube by a new one with the same anode material or whether the radiation should be swapped to a different one.
The ADAMAnT is available for all typical anode materials (Co, Cu, Mo, Ag) but currently only for horizontal setups, with plans for future availability in vertical configurations and conveniently, can be integrated into existing horizontal STADI P diffractometers.

StadiP2 reveal new 1536x1536
Rendering of a horizontal STADI P including the hardware for the ADAMAnT

STADi P for pdf data collection

As the demand for materials with lower degrees of order continues to rise, the significance of Pair Distribution Function (PDF) measurements is growing steadily. To measure best possible data for PDF interpretation, the STADI P can be installed with Ag Kα1 radiation and expanded with a PDF collimator, a MYTHEN2 4K detector and optionally air scattering shields, without any loss in diffraction data quality.

PDF comparison Zobel e1681221508789
This direct comparison of PDF data measured on the ionic liquid hmimPF6 shows how excellent our instrument performs versus a synchrotron. Plot from: doi.org/10.1063/1.5093714
STOE Transmission 054 bearb e1686834533942
PDF data is preferably collected in Debye-Scherrer geometry, which is beneficial for air sensitive samples.
PDF1 e1684828024312
With the MYTHEN2 4K detector in one-step mode you can measure up to 144° 2θ (2x 27° simultaneously, see the respective AppNote) in shortest time.
multimythenPDF e1684828157149
Shields can optionally be set on the detectors to reduce additional effects of air scattering
STOE Transmission 070 e1686834558935
For PDF measurements we offer a special collimator to reduce addittional background signal at high angles.

Software & Accessories

WinXPOW, is a uniquely designed powder diffraction software developed exclusively by our skilled team at STOE. It is meticulously crafted to perfectly work with our instruments, ensuring seamless compatibility and optimal performance. In addition to controlling the instruments, WinXPOW provides a comprehensive range of cutting-edge features. These include data reduction, profile fitting, pattern indexing, and spacegroup determination. Moreover, it boasts an array of powerful functionalities, such as advanced 2D and 3D graphics, among numerous other capabilities.

 

We provide a wide range of accessories to customize your sample environment according to your specific requirements. Our products encompass high temperature and reaction chambers, sample changers, dedicated battery cell holders, and various other accessories to enhance your experimentation capabilities.

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Sundy - Trung Quốc

SDACM3200 có thể được sử dụng để xác định nhiệt trị của chất cháy rắn và lỏng như than, than cốc, dầu mỏ, bột đen xi măng, nhiên liệu sinh khối cũng như vật liệu xây dựng. Mô hình hiệu quả nhất về chi phí với kết quả đáng tin cậy. Thời gian phân tích ≤14 phút
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

● Goniometer linh hoạt (giá đỡ Eulerian và nhiều thiết lập chi cố định khác nhau) ● Vùng nhiễu xạ có bán kính nhỏ hơn 0,005 mm ● Đầu dò pixel lai siêu nhanh (phạm vi đầu dò đầy đủ của EIGER và PILATUS)
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

● Nhiều đầu dò tia X đếm photon đơn. ● Phụ kiện nhiệt độ cao và thấp. ● Lựa chọn hình học bằng cách trượt vỏ ống.
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

● XRD nhỏ gọn, trọng lượng nhẹ, dễ dàng mang theo. ● Cho kết quả chính xác trong vòng vài phút. ● Phân tích ở bất cứ đâu / Goniometer góc rộng (0°-130°/ -3°-156°).
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

● Được thiết kế để kiểm tra nhiễu xạ tia X truyền qua tại chỗ đối với cell dạng túi. ● Thu thập đồng thời dữ liệu nhiễu xạ tia X của cực âm/cực dương. ● Phạm vi kiểm soát nhiệt độ: -30°C đến 300°C.
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

- Dòng AMI Meso112/222 được thiết kế để xác định diện tích bề mặt và kích thước lỗ xốp với độ chính xác cao của vật liệu dạng bột. Dòng sản phẩm này bao gồm hai mẫu, Meso 112 và Meso 222, cả hai đều được tích hợp bộ chuyển đổi áp suất 1000 torr tại mỗi trạm phân tích để xác định diện tích bề mặt BET chính xác và phân tích sự phân bố kích thước lỗ xốp trung bình. - Mỗi cổng phân tích được trang bị một mô-đun khử khí tại chỗ có khả năng làm nóng mẫu lên đến 400°C, đảm bảo loại bỏ hiệu quả các chất gây ô nhiễm hấp thụ trước khi phân tích. Quá trình khử khí tại chỗ này giúp loại bỏ nguy cơ ô nhiễm liên quan đến việc chuyển mẫu. Ngoài ra, khi sử dụng nhiều trạm, mỗi trạm hoạt động độc lập, cho phép phân tích đồng thời nhưng riêng biệt các mẫu khác nhau.
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

– Phân tích chất hấp thụ trong vật liệu, cho phép đo 02 mẫu đồng thời – Cân treo từ trang được bảo vệ mẫu để tăng cường phản ứng giữa mẫu và môi trường. – Phần mềm được sử dụng để kiểm soát cân và tính toán giá trị
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

- Thiết bị sử dụng phương pháp dịch chuyển khí (Gas displacement), với kết cấu nhỏ gọn, không cồng kềnh và các thao tác trở nên đơn giản hơn. - Phương pháp này với ưu điểm chính xác hơn và có khả năng tái tạo hơn so với phương pháp Archimedes truyền thống. Năm 2014, Tổ chức Tiêu chuẩn ISO Quốc tế đã chính thức giới thiệu phương pháp thay thế thể tích khí để kiểm tra tỷ trọng thực.
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

- STA – Phân tích nhiệt đồng thời là một phương pháp phân tích nhiệt áp dụng đồng thời phân tích nhiệt trọng trường (TGA) và phân tích nhiệt lượng quét vi sai (DSC) cho cùng một mẫu trong một thiết bị duy nhất. Các điều kiện đo phải hoàn toàn giống nhau đối với cả 2 tín hiệu TGA và DSC (cùng một bầu khí quyển, lưu lượng khí, áp suất hơi của mẫu, tốc độ gia nhiệt, tiếp xúc nhiệt với nồi nấu mẫu và cảm biến, hiệu ứng bức xạ, v.v.). - STA Series 650/1000/1200/1500 thế hệ mới của Advanced Measurement Instruments (AMI), tiền thân là Altamira, có hệ phân tích nhiệt đồng thời hiện đại, tích hợp độ phân giải cân siêu nhỏ 0,1 microgam, thuật toán điều khiển thông minh và thiết kế treo mẫu tối ưu. Kết quả là một hệ thống có độ chính xác cao, vận hành ổn định và chi phí hợp lý. STA Series cho phép thực hiện đồng thời TGA và DSC/DTA trên cùng một mẫu chỉ trong một lần chạy. Nhờ đó, người dùng tiết kiệm đáng kể thời gian và vật liệu, đồng thời thu được hồ sơ nhiệt toàn diện.
Liên hệ

Hãng sx: Advanced measurement instruments (AMI) - Mỹ

TGA – Phân tích nhiệt trọng trường là một phương pháp phân tích nhiệt được thực hiện trên các mẫu để xác định những thay đổi về trọng lượng liên quan đến sự thay đổi về nhiệt độ. Dòng thiết bị TGA Series 1000/1200/1500 của Advanced Measurement Instruments (AMI) mang đến khả năng phân tích nhiệt trọng lượng đạt chuẩn nghiên cứu với mức giá dễ tiếp cận, kết hợp hiệu suất vượt trội và chất lượng ổn định. Được trang bị vi cân siêu nhạy và lò nung hiện đại, nhỏ gọn, TGA Series đảm bảo độ chính xác cao, giảm thiểu hiệu ứng lực đẩy và cải thiện phản hồi nhiệt vượt trội.
Liên hệ