Hệ thống lò phản ứng để bàn μBenchCAT

Hệ thống lò phản ứng để bàn μBenchCAT

  • 249
  • Advanced measurement instruments (AMI) - Mỹ
  • Liên hệ
● Hệ thống lò phản ứng bán tiêu chuẩn, hoàn toàn có thể cấu hình: cổng khí, nhiệt độ và áp suất

● Hỗ trợ tối đa 6 đường cấp khí và 2 đường cấp chất lỏng

● Lên đến 1200°C và 100 bar (có thể tùy chỉnh cho nhiệt độ cao hơn)

Introduction

The μBenchCAT by Advanced Measurement Instruments (AMI) is a fully integrated, benchtop reactor system designed for comprehensive catalytic studies. Engineered for both gas-phase and liquid-phase reactions, it combines all essential components into a compact, automated platform—ideal for academic, industrial, and R&D environments.

With a variety of configurable options, the μBenchCAT offers exceptional flexibility, making it suitable for a wide range of applications, from catalyst screening and reaction kinetics to long-term stability testing and performance evaluation under real-world conditions.

Features

Maximum Operating Temperature: up to 1200°C, depending on reactor material

Maximum Operating Pressure: up to 100bar

Gas Feed Capability: Up to 6 independently controlled gas feeds

Liquid Feed Options: Configurable for 0, 1, or 2 liquid feeds

Reactor Materials: Available in stainless steel, quartz, or Incoloy to suit a wide range of chemical and thermal environments

Wetted Materials: Durable and chemically resistant components including Stainless Steel, PEEK, Kalrez, Viton, Incoloy, and Quartz

Isothermal Oven: Houses key process components in a uniformly heated environment, minimizing thermal gradients

Multi-Station Capability: Optional Dual μBenchCAT configuration allows for two stations to operate in parallel or series, enabling simultaneous or sequential experiments for enhanced productivity

Full Automation: Controlled through a LabVIEW-based interface for precise operation of temperatures, flows, valve sequences, and reactions

Redundant Safety Systems: Multiple layers of protection, including temperature safety switches, pressure relief valves, positive shut-off valves, firmware-level alarms, and software-based user alarms, ensuring safe and reliable operation

Connection to External Detectors

The μBenchCAT provides seamless integration with external analytical instruments. The product effluent can be routed to a gas chromatograph (GC) or other detectors via an optional sampling valve, available in heated or unheated configurations. This capability enables real-time product analysis and greater experimental insight.

Built-In Safety Systems

Every μBenchCAT is designed with a robust suite of hardware, firmware, and software-level safety features to ensure safe operation under demanding experimental conditions:

• Check valves in all gas and liquid feed lines prevent backflow and cross-contamination.
• Software-coded alarms continuously monitor temperatures and pressures. These alarms are configured by AMI based on system safety limits.
•User-defined alarm matrix allows operators to set custom upper and lower limits for key process parameters and define actions if thresholds are exceeded.

Built-In Safety Systems (continued)

• Hardware over-temperature safety switch protects the furnace from overheating.
• Firmware-level alarms safeguard all heating elements.
• Preset pressure relief valves prevent system over-pressurization.
• Front-mounted power switch provides immediate power cutoff in case of an emergency.
• Double fusing is included in all 220 VAC process equipment for added electrical protection.

These layered safety features ensure that the μBenchCAT can be operated confidently in both routine and advanced catalytic studies.

Software

The μBenchCAT is fully automated to ensure ease of operation, process reliability, and repeatability. Designed for unattended operation, it allows users to configure experiments with minimal manual intervention. The operator simply inputs a sequence of process parameters and control steps, schedules a start time, and the system handles the rest.

All key functions—including valve positions, flow rates, temperatures, pressures, and product sampling—are automatically controlled by the system’s operating software. Data readback is performed at a user-defined sampling rate, and all data are saved in a text-delimited format for easy import into external software platforms for further analysis or reporting.

Control and data acquisition are managed through a dedicated LabVIEW-based application, developed specifically for the μBenchCAT. This software provides intuitive control logic, real-time visualization of system status, and complete experiment tracking, making the μBenchCAT a powerful tool for both routine and advanced catalytic research.

The μBenchCAT software includes three distinct user access levels, allowing controlled operation and protection of critical system settings:

• Locked-Out Mode: This mode is intended for security or safety scenarios where system access must be fully restricted. In this mode, no control actions or changes can be made until authorized login credentials are provided.
• Operator Mode: Designed for routine users, this mode allows access to day-to-day functions such as loading saved procedures, starting/stopping experiments, adjusting basic run parameters, and viewing real-time data. Critical system configurations and calibration settings remain protected.
• Supervisor Mode: This mode provides full access to all system settings, including calibration routines, gas configurations, user management, method creation/editing, and advanced diagnostics. It is intended for experienced users responsible for system setup, maintenance, and high-level customization

AMI Instruments µBenchCAT
Software Screen

Applications

The μBenchCAT is engineered for high-performance catalytic testing in both gas- and liquid- phase environments. All core components are integrated into a compact, bench-top system, delivering precision, flexibility, and ease of use.

Reactor Feed System

The standard configuration supports up to 6 gas feeds and 2 liquid feeds. Each gas line includes a filter, electronic mass flow controller (MFC), check valve, and positive shut-off valve. The range and gas calibration of each MFC are specified by the customer to meet application requirements. Liquids are delivered via high-precision HPLC pumps (or liquid flow controllers), ensuring accurate and stable flow control.

Heated Isothermal Oven

An isothermal oven, operating up to 200°C, houses most process components to maintain a uniform thermal environment. This design minimizes condensation and ensures thermal stability throughout the system. Components located in the oven include:
• Integral gas preheater and liquid preheater/vaporizer, operable up to 300°C
• Feed mixer for combining gas and vapor streams
• Reactor by-pass valves for process flexibility
• Reactor furnace with control and safety thermocouples
• Reactor, equipped with an internal sample thermocouple for accurate temperature measurement

Condenser

A tube-in-tube condenser, located downstream of the reactor and outside the oven, ensures effective removal of condensable components. A thermocouple monitors the coolant return temperature, helping maintain thermal consistency and system stability.

Gas/Liquid Separator

Positioned after the condenser, the gas/liquid separator ensures efficient phase separation. Standard configuration includes high- and low-level switches to activate an automatic drain valve. An optional capacitance liquid level sensor is also available, offering continuous, precise liquid level monitoring for advanced level control and long-duration automation.

Pressure Control

Reactor exit pressure is measured via a dedicated pressure transducer. A high-turndown pressure control valve is used to build and regulate system pressure, enabling steady-state operation under pressurized conditions across a wide pressure range.

Product Sampling Valve (Optional)

An optional product sampling valve can route reactor effluent directly to an external analytical device, such as a gas chromatograph or mass spectrometer, enabling real-time product analysis and enhanced experimental insight.

BUILD A µBENCHCAT

 

Category Option Code
A. Number of Gases 0 G0
1 G1
2 G2
3 G3
4 G4
5 G5
6 G6
B. Number of Liquids 0 L0
1 L1
2 L2
C. Pressure / Temperature ATM / 1200°C 0
50 bar / 650°C 50
100 bar / 650°C 100
100 bar / 800°C 1008
D. Reactor OD 0.25 in 250
0.375 in 375
0.5 in 500
0.75 in 750
E. Reactor Material Quartz Q
316 Stainless Steel S
Inconel I
F. Gas / Liquid Separator No 00
One Stage 01
Two Stage 02
Three Stage 03
G. GC Sampling Line None 00
Unheated After Pressure Reduction 01
Heated slip-stream 02

Tập tin PDF:

Tập tin PDF:

Sản phẩm cùng loại

Hãng sx: Biuged Instruments - China

Dụng cụ này cung cấp một phương pháp dễ dàng để xác định độ cứng của màng cho lớp phủ được áp dụng cho bề mặt phẳng. Đầu bút chì, được chuẩn bị trước bằng cách cọ xát trên giấy mài mịn (400 ), được duy trì ở một góc 45º và được đẩy với áp lực đồng đều lên mẫu, để lại dấu vết bề ngoài hoặc gây phá hủy lớp nền. Nó phù hợp với các yêu cầu của ASTM D 3363, ISO 15184.
Liên hệ

Hãng sx: Biuged Instruments - China

- Nó phù hợp với các yêu cầu của ASTM D 3363, ISO 15184. - Dụng cụ này cung cấp một phương pháp dễ dàng để xác định độ cứng của màng cho lớp phủ được áp dụng cho bề mặt phẳng. - Đầu bút chì, được chuẩn bị trước bằng cách cọ xát trên giấy mài mịn (400 ), được duy trì ở một góc 45º và được đẩy với áp lực đồng đều lên mẫu, để lại dấu vết bề ngoài hoặc gây phá hủy lớp nền.
Liên hệ

Hãng sx: Biuged Instruments - China

Dụng cụ này cung cấp một phương pháp dễ dàng để xác định độ cứng của màng cho lớp phủ được áp dụng cho bề mặt phẳng. Đầu bút chì, được chuẩn bị trước bằng cách cọ xát trên giấy mài mịn (400 ), được duy trì ở một góc 45º và được đẩy với áp lực đồng đều lên mẫu, để lại dấu vết bề ngoài hoặc gây phá hủy lớp nền. Nó phù hợp với các yêu cầu của ASTM D 3363, ISO 15184.
Liên hệ

Hãng sx: Biuged Instruments - China

Đặc điểm : - Dụng cụ này cung cấp một phương pháp dễ dàng để xác định độ cứng của màng cho lớp phủ được áp dụng cho bề mặt phẳng. - Đầu bút chì, được chuẩn bị trước bằng cách cọ xát trên giấy mài mịn (400 ), được duy trì ở một góc 45º và được đẩy với áp lực đồng đều lên mẫu, để lại dấu vết bề ngoài hoặc gây phá hủy lớp nền. - Nó phù hợp với các yêu cầu của ASTM D 3363, ISO 15184.
Liên hệ

Hãng sx: Wira Instrumentation

Dễ dàng đo khối lượng sợi bằng thiết bị Wira tiện lợi Máy đo khối lượng sợi có thể được sử dụng để kiểm soát chất lượng (ví dụ: để kiểm tra sự thay đổi khối lượng giữa các bó sợi) và đảm bảo chất lượng (ví dụ: để kiểm tra khối lượng sợi mua). Nó cung cấp tính linh hoạt khi sử dụng vì nó cung cấp tùy chọn đo lường không phá hủy hoặc phá hủy.
Liên hệ

Hãng sx: Wira Instrumentation

Được thiết kế đặc biệt để kiểm tra số lượng sợi Thiết bị đo chính xác để xác định mật độ tuyến tính của sợi. Cân đếm sợi Wira là thiết bị lý tưởng để kiểm tra phân tích số lượng sợi. Các phép đo có thể xác định mật độ tuyến tính (khối lượng trên chiều dài) của các cuộn sợi và GSM (khối lượng trên mét vuông) của vải. Cân đếm sợi Wira đưa ra kết quả theo hệ thống Tex, dTex và các hệ thống đếm sợi khác như hệ mét (Nm), hệ Anh (Ne), hệ bông Anh (Nec), Denier (Td), v.v.
Liên hệ

Hãng sx: Wira Instrumentation

Đo nhanh độ căng của sợi dọc trong quá trình dệt Máy đo độ căng sợi dọc WTM:003 nhỏ gọn được phát triển để đo lực kéo trong sợi dọc. Lực kết hợp của sợi dọc có chiều rộng 50 mm được đo bằng đầu đo có con lăn 100 mm. Kết quả được hiển thị trên một thiết bị hiển thị riêng. Người vận hành có thể cài đặt lưu trữ các giá trị độ căng AVG, LAST, MIN, MAX, PEAK-MIN, PEAK-MAX trong thời gian đo.
Liên hệ

Hãng sx: Wira Instrumentation

FIND THE AVERAGE DIAMETER OF WOOL AND OTHER FIBRES QUICKLY USING THE WELL PROVEN AIR FLOW PRINCIPLE The new generation Wira Fibre Fineness Meter incorporates a colour touch screen interface, making the operation even easier. An on-board processor controls automatically the operation of the instrument and calculates test results for direct reading on the screen, and if required, relayed to a PC, using optional Windows software from where the results can be stored in an Excel file and reports printed.
Liên hệ

Hãng sx: RAPID (Labortex)

Lab Calender Model LC-250 is suitable for calendaring test by controlling pressure, heat and friction applied on fabric surface. The machine consists of two rollers placed vertically, the upper roller is made of Nylon, the lower steel roller as a heater, driven by a motor to rotate.
Liên hệ

Hãng sx: RAPID (Labortex)

Laboratory soaping machine model SP-12 is a 12-position unit used for after-treatment processes of dyed samples (yarn or fabric) as well as printed textiles. Samples are placed in different stainless steel pots, operators may add chemicals manually , then agitated them in the heating bath. Suitable for many kinds of after-treatment processes, such as soaping, scoring, bleaching, cotton burn-out in sulfuric acid, etc.
Liên hệ