Introduction

The PN-MRTF mask breathability tester is designed according to GB / T 32610-2016 and is used to test the inhalation resistance and exhalation resistance of the mask. This tester is suitable for medical and daily protective masks. Test principle: By wearing a protective mask on the head model of the simulator, and using the air pump to simulate the breathing action of the human body, the value of the pressure change of the pipeline caused by the obstruction of the air flow by the protective mask is tested to judge whether the breathability of the mask is qualified.

The tester has two test modes: inhalation resistance and breathing resistance 
 
Inspiratory resistance test:

Turn on the power of the tester, switch the breathing direction to the inhalation position, press the "inhalation" button, adjust the air flow adjustment knob, when it rises to (85 ± 1) L / min, the inhalation pressure is 0 at this time. Put the sample on the head mold, adjust the wearing position of the sample and the tightness of the headband to ensure the tight fit of the mask and the head mold. Then adjust the air flow adjustment knob. When it rises to (85 ± 1) L / min, record the inspiratory resistance value at this moment, and press the "Stop" key to stop the test. During the test, take appropriate measures to avoid the specimen from attaching to the mouth of the breathing tube.

Exhalation resistance test:
Turn on the power of the tester, switch the breathing direction to the exhalation position, press the "exhalation" button, adjust the air flow knob, when it rises to (85 ± 1) L / min, the exhalation pressure is 0 at this time. Put the sample on the head mold, adjust the wearing position of the sample and the tightness of the headband to ensure the tight fit of the mask and the head mold. Then adjust the air flow adjustment knob. When it rises to (85 ± 1) L / min, record the exhalation resistance value at this moment, and press the "Stop" key to stop the test. During the test, take appropriate measures to avoid the specimen from attaching to the mouth of the breathing tube.

Technical parameter

Power supply: AC220V±10%  10A  50Hz;
Flow meter: (10~100)L/min,accuracy:3%;
Micro pressure sensor range:±1500Pa;accuracy:1Pa
Air supply: >100L/min;
Ventilation: (85±1)L/min;
Head model size: Big, mid, samll, size according to GB/T 32610-2016 appendix B5.5;
Display: 7” touch screen;
Print: Modular integrated thermal printer;
Communication output: RS232 (standard) / USB (optional);
Working environment: indoor temperature (20 ± 10) ℃; relative humidity <85%;
Dimensions: 420 × 600 × 720 (L × W × H)

Product features

Adopt new module circuit design, with WIFI IOT function. After the network is connected, the test results can be saved to the cloud server, and the special QMS quality management system can be used to query and generate reports;
Easy to switch between inhalation resistance and breathing resistance;
Use DGUS color touch screen as the man-machine interface;
With statistical functions, it displays the average, maximum, minimum, standard deviation and coefficient of variation.

National standard

GB / T 32610-2016 "Technical Specifications for Daily Protective Masks
GB 2626-2019 "Respiratory Protection Self-priming Filter Anti-Particle Respirator