NOVICOLOR a modern, easy to use and feature rich Color-QC application for paper and Packaging industries and automotive supply chain members. It enables customers to analyze, report, communicate and visualize accurate color QC results. It incorporates the Indices, Tolerance Methods, Graphs and Light sources D65, C, UV ex .
Compatible with the following system software’s: Windows 7 / 8
Control and calibration of the device: Light source filtered according D65, C and UV ex level
Administration of the sample and standard library.
SPECIFICATION : | |
ILLUMINATION/VIEWING SYSTEM | Reflectance: d:0° (diffuse illumination, 0-degree viewing) Conforms to ISO 2469, JIS P8148, DIN 53145-1 and DIN 53145-2 standards. |
LIGHT-RECEIVING ELEMENT | Silicon photodiode array (dual 40 elements) |
SPECTRAL SEPARATION DEVICE | Diffraction grating |
WAVELENGTH RANGE | 360 nm to 740 nm |
WAVELENGTH PITCH | 10 nm |
REFLECTANCE RANGE | 0 to 200%; resolution: 0.01% |
LIGHT SOURCE | Pulsed xenon lamps (× 3) |
MEASUREMENT TIME | Approx. 1.5 seconds (for measurements of fluores- cent colors, at 9600 bps) |
MINIMUM INTERVAL BETWEEN MEAS- UREMENTS | Approx. 4 seconds; when reflectance measured, approx. 5 seconds; when fluorescent color |
MEASUREMENT/ILLUMINATION AREA | Ø 30 mm / Ø 34 mm |
INTER INSTRUMENT AGREEMENT | Mean ΔE*inferior at 0.2 (mean) |
REPEATABILITY | Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard deviation within ΔE*ab 0.02 (condition; white calibration plate measured 30 times at 10-second intervals) |
TEMPERATURE DRIFT | Spectral reflectance: Within +/- 0.10%/°C Color difference: Within ΔE*ab 0.05/°C |
UV ADJUSTMENT | Instantaneous numerical adjustment |
UV CUT FILTER | 400 nm cut-off and 420 nm cut-off |
CONTROL METHOD | Directly connected to a touch screen computer |
INTERFACE | RS-232C format |
POWER | 100-240V AC 50-60Hz 25W AC (with a dedicated AC adapter) |
DIMENSIONS (W × H × D) | 302 × 585 × 335 mm |
WEIGHT | 18.5 kg |
OPERATING TEMPERATURE/HUMIDITE | 13 - 33°C, relative humidity 80% or less (at 30°C) with no condensation |
STANDARD FOR CALIBRATION | ISO Level IR 3 |
COLOR / COLOR DIFFERENCE SCALES / TOLERANCES | Absolute and Delta values, dE for CIE XYZ, xyz, L*, a*, b*, C*, h*, u* v*, CIE, Opacity, Fluorescence, etc… |
PLOTS/GRAPHICS | CIELab, Trend, Histogram, Chromaticity, interactive zoom function |
GENERAL FEATURES | Statistic Std. deviation/mean avg. , descriptors, Configurable Data Grids |
MEASUREMENTS | Average measurements, Remote Measurements, Automated calibration timeout, manual Data input |
DATABASE FUNCTIONS | Store, retrieve, rename, delete Standards and Batches, Orga- nize Samples in a Folder Structure, Unique Sample Identifiers, |
EXPORT/IMPORT |
Export to ASCII file, Export result data to EXCEL |