ECS 8040 – CHNS-O Analyzer Organic Elemental Analysis

ECS 8040 – CHNS-O Analyzer Organic Elemental Analysis
zoom Zoom image
Price: 0 VND
Manufacturer: NC TECH - Italy
Quantity: 

Description

ECS 8040 is a C-H-N-S-O Elemental Analyzer Model based on the Dumas combustion method.

ECS 8040 is a state-of-the-art system for the elemental analysis based on sample combustion and separation of gases with a chromatographic column.

The combustion products, i.e. CO2, H2O, N2 and SO2, are separated and quantified by a high resolution TCD detector.

ECS 8040 is composed by: Singlefurnace combustion system (for a better combustion and optimization of catalysts) Safety quick fit system for reactors connection (easy and safe way to set the instrument) Customized GC column Detection system Data acquisition and handling ECS 80 SERIES ECS 8040 CHNS-O Several configurations may be set for the determination of the target element.

Typical configurations are for: CHNS; CHN; CN; CNS; O The versatility of ECS 8040 can be expressed as: Sample weight Sample type Liquid or solid sample Choose the best configuration by choosing the right chemicals, consumables and prepacked reactors.

 

Analytical and Technical Features

ECS 8040 Features

 

Type Analysis time

 

CHNS-O CN

 

 

5 min

 

CHN CHNS

8 min 10/25 min

 

Analytical range

O C H

4 min

0.002-20 mg

0.002-5 mg

 

N S

0.002-20 mg

0.002-6 mg

 

Accuracy* Precision*

O

<0.2% (certified standard; purity >99.9%)

<0.1% (certified standard; purity >99.9%)

0.002-2 mg

Sampler

Pneumatic autosampler Electronic autosampler Manual sampler

147 positions max

32, 50, 100 positions

Single furnace system Safety quick fit system Touch screen display Standby mode

Physical Specifications

Dimensions Weight

51x50x37 cm 53 kg

Power supply Adsorbed power

230V, 50/60Hz

4A, 900W

Gas requirements

Helium (99.999% purity), 3-5 bar

Oxygen (99.999% purity), 3-5 bar Air (oil free compressed air)

Analytical Conditions

 

Gas carrier Leak test

 

Helium Automatic

Furnace temperature Oven temperature

max 1100°C max 110°C

Oxygen volume need Flow rate

Gas separation

Automatically calculated by the oxygen doser Electronic Flow Rate

0.8-4 m GC Column

Detector

Software data analysis

High Sensitivity TCD EAS Clarity

Calibration Active calibration

Linear, Quadratic, Cubic As needed

Sample

 

Sample size

 

0.1-500mg (depending on sample nature)

 

Up to 1 g for soil samples

Sample type

Liquid

 

Solid

Capsule

High purity tin and/or silver capsule

 

Accessories

 

Installation kit Sampling kits

 

 

Small samples; big samples; deluxe kit

Microbalance Consumables

 

Proprietary NC Technologies S.r.l.


Application


Accessories


Video


Catalogue and User Manual


Download Catalogue
Download User Manual