ECS 8060 is a Nitrogen, Protein Analyzer Model making use of the Dumas combustion method. ECS 8060 is a state-of-the-art instrument for the elemental analysis based on sample combustion and separation of gases. The N2 combustion product is quantified by a high resolution TCD detector. CO2 is trapped in the innovative Zeoquantum system while H2O is condensed by specific Permapure trap.
Fully automatically operated: from the available samplers to the oxygen dosage, from the monitoring of consumables status to the zeolite regeneration system.
ECS 8060 Model is composed by:
✓ Dual furnace combustion system (for a better combustion and optimization of catalysts)
✓ Water extraction system by Permapure and water trap
✓ Carbon dioxide adsorption system by Zeoquantum
✓ Detection system ✓ Data acquisition and handling.
Very versatile, it is very useful for analysis of a wide range of sample types and sizes - both liquids and solids, from micrograms to grams of organic materials. Thanks to the absence of a GC column, sample weight limits are wider.
Pneumatic, electric and manual samplers and high quality consumables are available. Automatisms make ECS 8060 particularly user-friendly: the automatic oxygen dosage system allows a better consumption of oxygen and consumable status monitoring function optimizes the catalysts to be used. By the Zeoquantum CO2 adsorption system a large amount of carbon dioxide can be treated by an automatic regeneration system – resulting in more precision, greater performances in a shorter time.
When used in a C-N configuration, the simultaneous determination of nitrogen and carbon is attained. The exclusive designed TCD -Thermal Conductivity Detector -is self-calibrating so that no reference gas is needed. The ECS 8060 is particularly suitable for linking to other units for determination of the isotopic ratios of carbon stable isotopes.
FEATURES AND BENEFITS
Analytical and Technical Features
ECS 8060 Features
Type N - Proteins
Analysis Time N – from 4 min up to 8 min
Analytical Range From 0,002 up to 20 mg
Accuracy* <0,2% (certified standard; purity >99.9%)
Precision* <0,1% (certified standard; purity >99.9%)
Sampler Pneumatic
autosampler 147 positions Electronic
autosampler 32, 50 100 positions
Manual sampler -
Dual Furnace System
Safety Quick-fit Integrated water trap
Zeoquantum CO2 adsorption and desorption system
Touch-screen display
Stand-by mode
Physical Specifications | |
Dimensions | 98x50x37cm |
Weight | 78kg |
Power Supply | 230V, 50/60Hz |
Absorbed Power | 5A, 1100W. |
Gas Requirements | Helium (99.999% purity), 3-5 bars |
Oxygen (99.999% purity), 3-5 bars | |
Air (oil free compressed air) |
Analytical Conditions | |
Gas carrier | Helium |
Leak test | Automatic leak test |
Furnace temperature | Left furnace :1100°C max Right furnace: 1100°C max |
Oxygen volume need | Automatically calculated by the oxygen doser |
Flow Rate | Electronic flow rate control |
Water trap | Efficient and easy maintenance |
Detector | High Sensitivity TCD |
Detector | High Sensitivity TCD |
Detector | High Sensitivity TCD |
Software data analysis | EAS Clarity |
Calibrations | Linear, Quadratic, cubic |
Active calibration | As necessary |